Description

Plumbonline have extended our solar hot water spare parts catalogue to include the Resol range of solar differential controllers. We have all the major spare parts for your solar hot water service wether it be flat plate panels or evacuated tubes. The solar hot water parts range is now online and ready to order with complete tech specs to ensure your seamless selection. If you’re unsure which part suits, Plumbonline has a committed team of specialists with over 30 years of solar hot water selection experience.

Solar thermal or hot water technology taps the infinite energy resources of the sun to face the ecological responsibility of tomorrow. Solar thermal systems are operated and controlled by solar controllers. RESOL differential temperature controllers are used in solar, heating and air-conditioning systems to initiate switching processes depending on thermal, hydraulic and environmental conditions. Apart from these basic functions, RESOL controllers offer a variety of options and functions for the optimum use of individual solar and heating systems. All RESOL products are future-oriented, sophisticated and unique in their design. 

The DeltaSol® AL solar controller

Simple solar controller with extra convenience!

DeltaSol AL is a temperature differential controller that offers all the vital functions for a standard solar thermal "Hot water" system. The controller is equipped with the comprehensive System-Monitoring-Display, which shows the system parameters quickly and easily.

For data communication, the controller has a VBus®. Operation and function control are simple as usual.

DeltaSol AL features

  • System-Monitoring-Display
  • Up to 3 Pt1000 temperature sensors
  • Heat quantity measurement
  • Function control
  • Operating hours counter
  • Intuitive operating concept
  • Unit °F and °C selectable

Technical data

  • Inputs: 3 Pt1000 temperature sensors
  • Outputs: 1 electromechanical relay (changeover)
  • Switching capacity: 4 (1) A 240 V~ (electromechanical relay)
  • Total switching capacity: 4 A 240 V~
  • Power supply: 100 … 240 V~ (50 … 60 Hz)
  • Supply connection: type Y attachment
  • Power consumption < 0.7 W (Standby)
  • Mode of operation: type 1.B action
  • Rated impulse voltage: 2.5 kV
  • Data interface: RESOL VBus®
  • VBus® current supply: 35 mA
  • Functions: function control, operating hours counter, tube collector function and heat quantity measurement
  • Housing: plastic, PC-ABS and PMMA
  • Mounting: wall mounting, also suitable for mounting into patch panels 
  • Indication / Display: System-Monitoring-Display for visualisation, 16-segment display, 7-segment display, 8 symbols for system states, background illumination
  • and operating control LED
  • Operation: 3 push buttons and 1 slide switch
  • Protection type: IP 20 / DIN EN 60529
  • Protection class: II
  • Ambient temperature: 0 … 40 °C [32 … 104 °F]
  • Degree of pollution: 2
  • Dimensions: 144 x 208 x 43 mm

What is a Differential Controller and what does it do?

A solar hot water differential controller is the logic controller that manages your solar hot water system, most solar hot water systems consist of four main parts,

  1. The Solar Collector / Array, they can be flat plate or evacuated tube
  2. The Hot Water Storage Tank
  3. The Solar Transfer or Circulating Pump
  4. The Differential Controller.

The controller obtains the most energy from your solar collector, and the pump transferes the energy to the hot water tank. in their most basic format they continually measure the hot water tanks temperature, and the temperature of the solar collector manifold. When you draw stored hot water the tank cools down, the sensor in the tank has a set point the controller measures the difference between the tank temperature and the set point temperature in the solar collector. If the set point is reached the controller starts the circulating pump which transfers the hot water to the insulated storage tank for future use.